Mammography - Planmed Sophie Classic & the new Planmed Nuance... Planmed Sophie Classic.
Unit Configurations Planmed Sophie is available in three physical configurations ・
Planmed Sophie can be configured for film, Spot Digital, and Full Field Digital; and it can operate in conjunction with (for example) the recently released FUJI Mammo CR system for optimum digital imaging performance and realistic costing. Please ask for details
Digiguide system - also showing the special bracket available for the lateral approach
The Planmed SOPHIE Classic Mammographic Unit is an sophisticated instrument incorporating a range of advanced features, and with simple Operator control operation.・. キ Microprocessor controlled system design with full internal diagnostics and management. キ 80 kHz high performance Generator with 0.1/0.3 mm focal spot tube for outstanding image quality and low patient dose. キ Automatic line voltage management; auto tube thermal loading and shutdown management. キ Enhanced ergonomics, and with dual control panels for convenient operation. キ Motorised drive functions for C Arm movement. キ Efficient patient compression Paddles with easy lock-in facility. キ Intelligent AEC, computer controlled to optimise contrast, and with minimum dose. Three solid state detectors are combined with 15 density steps and 9 pre programmed film/ screen combinations for complete operator control of image quality. AEC and AAEC (auto kV) modes included. キ Optional Rhodium filtration with automatic selection. キ Adjustable Magnification from 1.3x to 1.8x キ Integrated stereotactic Planmed Cytoguide (see below) キ Prepared for the optional digital imaging. キ Prepared for MaxView upgrade キ Modular design for easy upgrades Generator: Constant Potential 80 kHz, computer controlled. 120 mA large focus; and 42 mA fine focus output. (Varian tube) 20 - 35 kV output. 10 - 500 mAs range. X Ray Tube: Toshiba Rotating anode 300,000 HU Molybdenum target. 0.1/ 0.3 mm foci, with biased focal spots. High speed, biangular anode. Be. Window, Mo filter, and optional Rh Filter included. Outputs ・Large focus 110 mA, small focus 35 mA. (NOTE: alternative Varian tube available with 120 mA & 42 mA outputs)C Arm: Motorised isocentric movement with range of +180/ - 135 degrees with quick selectable reference projections, adjustable speeds etc. Vertical range over 750 - 1350 mm with two speed motor drive. Optional version optimized for wheelchair patients with cut ・away base (extra cost option) Diaphram motorized, continuously adjustable radiation field with inbuilt illumination and built in spot diaphram. S.I.D. 650 mm. Compression motorized, dual system with selectable degressive speeds, fine adjustment for compression force, and auto or manual release after exposure. Two foot controls plus hand controls. Magnification integrated, motorized and continuously adjustable over the range of 1.3x to 1.8x as measured from the centre plane of a 5cm thick breast. Compressed thickness digitally displayed. Biopsy Paddle with cutout section for needle access. Film marking automatic, and inbuilt. Bucky assemblies for 18 x 24 and 24 x 30 cm cassettes and rectangular compression Paddles included. Auto Exposure Control AEC or advanced AAEC with auto kV control. Sensors are solid state. Density control in 15 steps (13% change each step) Planmed Cytoguide stereotactic unit Microprocessor controlled with robotic programs. Optimised rotation geometry for high accuracy Precise microprocessor controlled on-line needle holder movements. Fine adjustments in steps of 0.1 mm in all directions. Operator, Technical & Parts Manuals Typical offers include the following items ・o:p> o Planmed Sophie Classic Mammographic systemo Bi-angular, high speed tube |
|||||||||||||||||||
|
|
Home |
About MIT |
Products |
Service Support |
Links |
Contact Details |
Components |
|
|||||||||||||||||||